A] -
Alexandria Engineering Journal (2015) xxx, xxx-xxx
HOSTED BY
ELSEVIER
Alexandria University Alexandria Engineering Journal
www.elsevier.com/locate/aej www.sciencedirect.com
Improvement of Methylene Blue removal by electrocoagulation/banana peel adsorption coupling in a batch system
Helder Pereira de Carvalho a,% Jiguo Huang a, Meixia Zhao a, Gang Liu a, Lili Dong b,c, Xingjuan Liu a
a Key Laboratory of Groundwater Resources and Environment, Ministry of Education, Jilin University, Changchun 130026, PR China b Key Laboratory of Songliao Aquatic Environment, Ministry of Education, Jilin Jianzhu University, Changchun 130118, PR China c School of Environment, Northeast Normal University, Changchun 130117, PR China
Received 16 September 2014; revised 31 March 2015; accepted 5 April 2015
KEYWORDS
Electrocoagulation; Banana peel; Adsorption; Methylene Blue; Kinetics;
Energy consumption
Abstract The present work studies the improvement of Methylene Blue (MB) from aqueous solutions by an electrocoagulation (EC)/banana peel (BP) adsorption coupling process. The kinetics of this coupling process was studied using different amounts of adsorbent material in order to identify the most appropriate dosage, for enhancing wastewater treatment. The influence of current density on the removal efficiency and energy consumption of the EC/BP coupling process was also determined.
The coupling between electrocoagulation and BP showed that the addition of an appropriate BP dosage resulted in the enhancement of the removal rate of dyes especially at lower current densities, and in a considerable reduction in the contact time compared to the conventional simple EC process and simple adsorption process, having achieved efficiency removal of approximately 99%.
Based on the high removal efficiency, short contact time and low energy consumption, the EC/BP coupling method could be recommended instead of the conventional simple EC. © 2015 Faculty of Engineering, Alexandria University. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
1. Introduction
The disposal of textile wastewater is currently a major problem from a global viewpoint [1]. It has gained increased attention because the extensive release of synthetic dyes has caused considerable environmental pollution [2]. Importantly, the
* Corresponding author. Tel.: +86 13604436250.
E-mail address: helarc2008@gmail.com (H.P. de Carvalho).
Peer review under responsibility of Faculty of Engineering, Alexandria
University.
accumulation of dyes in water can seriously damage food chains of human and animals [3,4]. Gupta Suhas [5] pinpointed the need of some systematized studies on separation/degradation processes of dyes, and the consideration of wastewater treatment at the source underlines the importance of developing technologies that are simple, reliable, adaptable and relatively cheap. In this way, an increasing interest has been shown in combining process such as electrocoagulation, electro-oxidation, adsorption, ozonation [6] and reverse osmosis [7].
http://dx.doi.org/10.1016/j.aej.2015.04.003
1110-0168 © 2015 Faculty of Engineering, Alexandria University. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
The electrocoagulation process provides a simple, reliable, and cost-effective method for the treatment of wastewater without the need for additional chemicals, and thus, without the production of secondary pollution [8-11]. It also reduces the amount of sludge which needs to be disposed [12]. The separation by electrocoagulation of pollutants such as hydrocarbons [13,14], dyes [15-18], heavy metal ions [19,20], leachate [21], and various other ions such as boron [22] and fluorine [23] has been reported.
EC utilizes a direct current source between metal electrodes partially submerged in electrolyte. The electric current causes the dissolution of the metal plates into the wastewater [24]. The most widely electrode materials are aluminum and iron, because they are cheap and very effective [25]. In the case of electrocoagulation with Al, the anodic reaction leads to soluble Al3 + :
Al(s) ! Al3+ + 3e" (1)
and the cathodic reaction produces hydroxide ion and H2 gas: 3H2O + e- ! (3/2)H2(g) + 3OH- (2)
Some researchers consider that reaction shown in Eq. (3) occurs to form amorphous Al(OH)3 (gel) [26,27]. The flocs formed of the amorphous Al(OH)3 have large surface area, which is beneficial for rapid adsorption of soluble organic compounds and trapping of colloidal particles [24].
Al3+ + 3OH-! Al(OH)3(gel) (3)
Other researchers suggest that the reaction shown in Eq. (4) takes place at the metal-solution interface before Al(OH)3(gel) can be formed in solution. The soluble Al(OH)4- species is a precursor for Al13 polymer formation, the most effective specie of polyaluminum coagulant [28-30]. The Al13 polymer removes soluble organic compounds by charge neutralization and sweep flocculation [31]. Decolorization efficiency mainly depends on the total dissolved aluminum (AlT) and the ratio of Al13 polymer to AlT [24]. In fact, dye removal from wastewaters is a combined effect of the actions of Al(OH)3(gel) and Al13 polymer [26,32].
Al3+ + 4OH- ! Al(OH)- (4)
On the other hand, Avsar et al. stated that the main disadvantage of conventional EC consists in the formation of an impermeable oxide film on the cathode [33], resulting in higher energy consumptions and lower efficiencies [33-37]. One of the ways to enhance conventional EC systems aside from the changing polarity of electrodes [38] has been suggested by Narayanan and Ganesan, who reported the use of granular active carbon (GAC), which might be a more efficient and faster separation technique compared to conventional EC [39]. Similar studies have also been reported by Secula et al. [40,38]. On the other hand, coupling the electrocoagulation technique with BP adsorption was not reported before, and it deserves attention because BP is an effective and low-cost coagulant and therefore ideal for application in developing countries.
The main aim of the present work was to investigate the efficiency of coupling the electrocoagulation technique with BP adsorption for removing Methylene Blue from aqueous solution. Cell voltage and solution pH were monitored during the electrocoagulation process. The unit energy demand
(UED), the unit electrode material demand (UEMD) and the charge loading (Qe) were also determined and discussed. A pseudo-first order kinetic model was tested on both simple EC and EC/BP coupling processes to determine the values of rate constant and half time under various experimental conditions. Based on the rate constant values and energy consumption (Econ), optimization of the coupling process by adding different amounts of BP was evaluated. The influence of current density on the enhancement of removal efficiency and Econ of the EC/BP coupling process was established.
2. Experimental
2.1. Materials
Bananas were purchased at a local market (Changchun, China) and were manually peeled immediately. The banana peels were washed with distilled water to remove the surface adhered particles and water-soluble materials. Then it was sliced, spread on trays and over dried at 60 0C for 48 h. The dried slices were ground and sieved to obtain a particle size range of 60 mesh and stored in plastic bottle for further use. No other chemical or physical treatments were used prior to experiments.
Methylene Blue (MB, C.I. No. 52015, C^H^Cl^S ■ 3H2O, MW = 373.90 gmol-1), was purchased from Shanghai Jinsui Bio-Technology Co., Ltd. (Shanghai, China) (Fig. 1).
Solutions of MB (volume 1 L) were prepared before each experimental run by dissolving certain amounts of dye in ultra-purified water.
To adjust the solution conductivity, a weight of 1 g of NaCl (Beijing Shiji, Beijing Chemical works, China) was dissolved in synthetic dye solutions (volume 1 L).
2.2. Electrocoagulation experiments
The electrocoagulation reactor consisted in a parallel-plate electrocoagulation cell provided with two facing electrodes and with six perforated tubes attached to its bottom to maintain a uniform gas flow and stirring into the cell. The experimental setup used in this study is shown in Fig. 2. The effective area of the each electrode plate was 97 cm2. The anode and cathode were positioned vertically and fixed at a distance of 1 cm from each other. The electrodes were aluminum and stainless steel (SS-304) plate connected to a digital DC power supply (WYJ, 0-30 V; 0-5 A; DC Regulated Power Supply Double Way Output, TESTMART, Shanghai, China). The electrodes were polished with fine-grained emery paper, washed with 1 N H2SO4 and then with distilled water before each run. All the runs were performed at room temperature 20 ± 1 0C.
Figure 1 Chemical structure of Methylene Blue.
Figure 2 EC experimental setup: 1 - anode (aluminum); 2 -cathode (stainless steel); 3 - reactor; 4 - aquarium air pumps with two outlets; 5 - perforated tubes; 6 - DC power supply.
The experiments were carried out in batch mode. In each run (time interval of 1 h), 1000 cm3 of 50 mg/L dye solution was placed in the electrochemical cell and three aquarium air pump with two outlets (SOBO SB-648, max output: 2 x 4 L/ min, Zhejiang, China) was used to supply needed air to the bottom of the reactor through the perforated tubes. The current density was set to a desired value and then coagulation was started. The pH of the solution was measured by a PHS-3E pH meter (Shanghai INESA and Scientific Instrument Co., Ltd, China).
During experiments samples were taken at different time intervals (5; 10; 15; 20; 25; 30; 40; 50; 60 min). Approximately 5 mL of sample was taken, allowed to settle, filtrated by means of Whatman 0.45 im filters, and then analyzed. For all the experiments, a total of 60 cm3 samples were taken to assess the treatment progress.
The concentration of MB was determined at 665 nm using a SDPTOP UV2600PC UV/VIS Spectrophotometer (Shanghai Sunny Hengping Scientific Instrument Co., Ltd, China).
The color removal efficiency (Y (%)) was calculated from
Y = (Co - Ct)/Co * 100
where Co is the concentration of dye before electrocoagulation (mg/L), and Ct is the concentration of dye after t min of electrocoagulation (mg/L).
The concentration of dye was determined using the initial calibration curve which was recorded after spectrophotometric measurement of the solution absorbance for dye standard concentration at the specific wavelength corresponding to the maximum absorption of dye.
The FTIR spectrum of the dried BP was obtained on an FT-IR Shimadzu 8400 s spectrophotometer. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX) of the adsorbent before and after adsorption was examined by a Shimadzu XD-3 Scanning Electron Microscope equipped with EDX analyzers.
2.3. Unit energy and electrode material consumptions, charge loading and energy consumptions
The most important costs of electrocoagulation technology are related to the consumption of electrical energy and electrode material [38].
When EC tests are conducted in galvanostatic regime, i.e., the current intensity is maintained constant, the cell voltage varies. Therefore, the energy consumption related to the
amount of removed dye, unit energy demand (UED, kW h/kg) [41,42], can be determined by means of the following relationship:
UED = -
I -IÔU ■ dt
1000 ■ V ■ Co ■ t0o
where U - cell voltage, (V); I - current intensity, (A); t - time, (h); V - volume of treated solution, (m3); Yt - color removal efficiency at time t, (%).
The generation of coagulant during EC process leads to the consumption of electrode material that can be estimated based on Faraday's law [43] as follows:
n F V Co 100
where UEMD - unit electrode material demand, (kg/kg); t - time, (s); n - number of electrons involved in oxidation/reduction reaction; F - Faraday's constant, (C/mol); A - atomic mass of electrode material, (g/mol).
The charge loading (Qe) and energy consumption (Econ) per gram of dye molecule were calculated using Eqs. (8) and (9) [44].
Qe = ItEC/Co
Econ = UItEC/Co (9)
where Qe - charge loading per gram of dye (Ahg-1), Econ - specific electrical energy consumption per gram of dye (W h g-1), Co - initial dye concentration (g), I - current (A), U - cell voltage (V), and tEC - electrolysis time (h).
2.4. Determination of rate constant
In the processes investigated, conventional electrocoagulation and coupling, the rate of MB removal is proportional to the concentration of dye, the amount of aluminum hydroxides formed and BP added [45] as follows:
-dC/dt = kCCads (10)
where C is the concentration of dye (kg/m3), and Cads refers to the concentration of adsorbents present in the system (kg/m3), aluminum hydroxides in case of conventional EC, and aluminum hydroxides and BP in the case of the coupling process. Since the generation of aluminum hydroxide can be assumed constant for a given current density, Eq. (10) can be reduced to pseudo first order kinetics:
-dC/dt = kiC (11)
The integration of Eq. (11) results in
ln(Co/C) = k ■ t (12)
The rate constant k1 can be estimated from the plot ln(Co/C) versus electrocoagulation time.
3. Results and discussion
The effect of BP material on the removal of MB by electroco-agulation was evaluated. MB can be correctly adsorbed onto the considered BP. The EC technique also proved to be very effective and relatively cheap compared to the simple adsorption process by BP. By coupling BP adsorption with the EC
technique it was expected that the overall rate constant of dye removal would be enhanced.
3.1. FT-IR spectroscopy, scanning electron microscopy and energy dispersive X-ray analysis of banana peel
The FT-IR spectra of BP were taken before and after the adsorption of MB to ascertain the possible involvement of the functional groups on the surface of BP in the adsorption of MB (Fig. 3). Fig. 3a shows a number of peaks, indicating the complex nature of the adsorbent. Bands appearing at 3313.4, 2920.3, 2850.6, 1734, 1613.6, 1317.4, 1035.2 and 884.6 cm-1 in Fig. 3a were assigned to OH stretching, C—H stretching of alkane, C—H and C=O stretching of carboxylic acid or ester, COO- anion stretching, OH bending, C—O stretching of ester or ether and N—H deformation of amines respectively [46]. Out of these, carboxylic acid and hydroxyl groups played a major role in the removal of MB. On the other
hand, Fig. 3b reveals that some new bands appeared, some remained and some were shifted after MB sorption. The bands at 3500, 3313.5, 2920.3 and 1613.6 cm-1 were shifted to 3846.3, 3336, 2906.3, 1622.9 cm-1 after MB adsorption. This is an indication that OH, C—H, C=C and C=O, carbonyl group could be involved in the adsorption of MB onto BP.
The SEM image of BP before adsorption (Fig. 4a) shows that the peel particles pores are highly heterogeneous. However, after adsorption, a significant change in the structure of the peel is observed (Fig. 4b). The peels appear to have a rough surface with crater-like pores because they are partially covered by MB molecules.
In order to know the composition of BP, elemental analysis was done with the use of EDX analysis. The EDX analysis of unadsorbed BP, shown in Fig. 4c, showed the presence of various elements along with a high amount of potassium. The difference in peak intensities of each element before and after adsorption (Fig. 4d) as well as the presence of additional
Wavenumbers(cnrv') Wavenumbers (cm-'
Figure 3 FTIR characterization of BP before (a) and after (b) MB adsorption.
Figure 5 Abatement rate of Methylene Blue at different values of current density (a) without BP and (b) with 5 g of BP; [MB]0 = 50 mg/ L, [NaCl] = 1 g/L.
peaks after adsorption (such as N, Na, and Al), demonstrates the change of the characteristics of the BP, and confirms the adsorption phenomenon.
3.2. Influence of current density
Current density not only influences coagulant dosage but also bubble formation rate, their size and the flocs growth [47]. In order to establish a favorable value of current density for the EC/BP coupling process, four values of current density, 2.5, 5, 7.5 and 10 mA/cm2, were chosen to be applied during simple EC and EC/BP processes to evaluate the effect on decoloriza-tion over a wide range of current density parameters. In Fig. 5, the abatement rate produced by the two processes investigated is compared.
Compared to the simple EC technique, the addition of a quantity of 5 g/L of BP in the electrocoagulation cell resulted in faster decolorization. The highest enhancement of
decolorization by adding BP was obtained at low current density values, although even at high current density values the separation process was significantly improved. The rapid removal of MB can be attributed to the fact that the system suffered both reactions simultaneously, electrocoagulation and also adsorption process. In all the experimental investigations presented below, a current density of 2.5 mA/cm2 was therefore applied in order to demonstrate the effects of the BP dose and dye initial concentration on the removal efficiency and operations related to the consumption of electric energy.
3.3. Influence of BP dosage
Fig. 6 compares the evolution of the removal efficiency of dyes for simple EC and for EC/BP coupling at different BP dosages demonstrating the influence of the amount of BP on the removal efficiency.
Figure 7 Pseudo-first kinetics of EC/BP coupling process at several doses of BP. [MB]0 = 50 mg/L, [NaCl] = 1 g/L, CD = 2.5 mA/cm2.
Table 1 Kinetic parameters of simple electrocoagulation and electrocoagulation/BP coupling for several amounts of BP.
concentration (g/L)
Pseudo-first order model
k0-10 t1/2 (min) k10-60 t1/2 (min)
(min^1) (min^1)
0.0 0.02181 31.781164 0.00661 104.863416
0.2 0.03248 21.340738 0.0181 38.295424
0.4 0.12687 5.463444 0.00536 129.318504
0.8 0.09256 7.488626 0.00945 73.348908
2.0 0.16841 4.115831 0.01967 35.238799
3.0 0.2159 3.210501 0.01383 50.119102
5.0 0.33553 2.065828 0.00379 182.888438
6.0 0.24742 2.801500 0.0101 68.628434
7.0 0.2667 2.598977 0.00763 90.844978
Figure 8 Activity-pH diagram for Al(III) species in equilibrium with Al(OH)3 (amorphous).
It can be seen that adding low amounts of BP, e.g. 0.2 g/L, does not increase significantly the removal efficiency compared with no addition of BP. The addition of a quantity of BP above 2 g/L or more has a strong influence on dye removal
from the very beginning of the electrocoagulation/BP process. As the BP dosage is increased, maintaining the other parameters constant, the removal efficiency of MB becomes significantly higher and the contact time for obtaining 97% removal efficiency decreases until 5 min. Although higher dosages of BP above 5 g/L lead to a low level of the remaining MB, we should take into account that an excessive amount of coagulant may provoke not a very effective procedure, as the BP will remain without coagulant, dissolved in water [48].
Fig. 7 shows the results of the kinetics investigations of elec-trocoagulation/BP coupling at different doses of BP. It shows that, in the first 10 min of coupling process, the MB depletion is a pseudo-first-order reaction and also shows that a pseudofirst order reaction might describe the behavior for the system over the 10-60 min period. However, in this case the values of rate constant (k) were lower compared with the first 10 min of the electrocoagulation (Table 1). This was probably due to the fact that during oxidation there is a formation of intermediates that are more difficult to remove [49]. A similar behavior was observed by other researchers [50,51].
3.4. Variation of solution pH during EC/BP coupling
The role of pH in EC process is very important [52]. pH affects Al(OH)3 stability in the solution [52]. Fig. 8 demonstrates different forms of Al(OH)3 relative to the pH and concentration of Al3+ ions in the media [53]. In the high and low pH, Al(OH)3 is in its charged form and is soluble in water, hence, cannot be used for EC. But in neutral pH, Al(OH)3 is stable and insoluble in the water and available for pollutant adsorption from water [52].
Some studies reported in the literature claim that controlling pH in iron-based electrocoagulation processes leads to higher efficiencies [42]. However, the mechanism of electroco-agulation depends mainly on the nature of the pollutant [54,55]. Recently, Secula et al. [56] found that the addition of acid solution to control the pH value of the treated solution in fact limits the development of the flocs generated.
Fig. 9 shows the influence of the amount of the BP on the solution pH during the EC/BP coupling process. As expected, the increase in BP dose leads to a low final pH of the treated effluents, making it possible for the EC/BP coupling process
Figure 9 Variation of pH value during EC/BP coupling process, at several doses of BP ranging between (a) 0 and 2 g/L, (b) 3 and 7 g/L. [MB]0 = 50 mg/L, [NaCl] = 1 g/L, CD = 2.5 mA/cm2.
to be conducted at a more favorable pH value (neutral pH), consequently, creating stability of Al(OH)3 in the water for pollutant adsorption.
3.5. Influence of the dye initial concentration
This parameter was investigated in the range of 50-300 mg/L. Fig. 10 shows that the increase of the dye initial concentration causes a reduction in color removal conversion. With increasing the dye initial concentration while amounts of the coagulant are constant, the adsorption capacity of flocs becomes insufficient and a reduction in color removal conversion will occur [52].
3.6. Unit energy demand, electrode material consumptions, charge loading and energy consumptions
3.6.1. Unit energy demand
Fig. 11 presents the influence of different amounts of BP on the evolution of UED determined according to Eq. (2).
It can be seen that adding amounts of BP results in an increase of UED values with contact time, except for quantity of BP between 5 and 7 g/L which had significant fluctuations in the values of UED, and consequently had a negative influence on dye removal once the removal efficiency decreased. It is more notorious especially at durations above 20 min of EC/BP coupling.
3.6.2. Electrode material consumptions
Fig. 12 shows the influence of different amounts of BP on the evolution of UEMD determined according to Eq. (3).
It can be seen that the longer contact time of the system applied, the weight of the electrode consumed in the simple EC and EC/BP coupling process has been increased. It also notorious that amount in excess of BP (above 5 g/L) leads to significant decreases in the electrode consumption and consequently the removal efficiency of MB dye also decreases.
Figure 11 Variation of UED as a function of BP dose at several values of contact time.
Figure 10 Influence of initial concentration of the dyes on the color removal conversion. [NaCl] = 1 g/L, CD = 2.5 mA/cm2.
Figure 12 Evolution of unit electrode material unit (UEMD) during EC/BP coupling as a function of BP dose at several values of contact time.
3.6.3. Charge loading
Fig. 13 shows the influence of different amounts of BP on the evolution of Qe determined according to Eq. (4).
As expected, an increase of contact time leads to significant increase in the Qe value. It can be seen that when the amount of BP in solution increases, the Qe value increases. Also, adding amounts of BP above 5 g/L led to large fluctuations in the values of Qe, affecting negatively the efficiency of the EC/BP coupling process.
3.6.4. Energy consumptions
The variation of electrical energy consumption (determined according to Eq. (5)) with the contact time for simple EC and for EC/BP coupling at different BP dosages is presented in Fig. 14. It is shown that the electrical energy consumption
Figure 13 Evolution of charge loading (Qe) during EC/BP coupling as a function of BP dose at several values of contact time.
The addition of BP as adsorbent resulted in a rapid increase in the removal efficiency of MB especially at lower current densities and operating times compared with the conventional electrocoagulation process. The success of this coupling process is linked to the specific chemical and textural properties of the material and the best conditions found were used for the electrocoagulation/banana peel coupling.
The removal rate and energy consumption were found to increase when the current density was increased from 2.5 to 10 mA/cm2.
Increasing the dosage of BP from 0.2 to 7 g/L improved the kinetics of the coupling process rapidly (5 min was sufficient to remove almost all color «97%). However, in terms of energy consumption and removal efficiency a dosage of 5 g/L is optimal, and further increases resulting in insignificant increase and reductions in energy consumption, affecting negatively the efficiency of the EC/BP coupling process.
It was shown that the EC/BP coupling technique for MB removal is considerably cheap, and is suitable for developed and developing countries.
Acknowledgments
0 10 20 30 40 50 GO
t(min)
Figure 14 Variation of energy consumption in the absence and at different doses of BP. [MB]0 = 50 mg/L, [NaCl] = 1 g/L, CD = 2.5 mA/cm2.
ranging from 0 to 1.65 W h g-1 increased proportionally with contact time (0-60 min) for both electrocoagulation processes (simple EC and EC/BP coupling). In first 5 min, the energy consumption for the EC/BP coupling process with the optimal dosage did not differ with the process of simple EC which is roughly 0.07 W h per gram of dye, having increased in relation to simple EC for contact time above 10 min.
4. Conclusions
In this work we discussed the effects of dye removal by EC/BP coupling on decolorization and energy consumptions in comparison with simple EC. It was found that the removal of MB by electrocoagulation using aluminum (anode) and stainless steel (cathode) and adsorption using BP are feasible processes.
This research was supported by the Natural Science
Foundation of Science and Technology Agency of Jilin
Province (No. 20130101091JC) and the National Natural Science Foundation of China (No. 51308252).
References
[1] M.A. Ahmad, N.A.A. Puad, O.S. Bello, Kinetic, equilibrium and thermodynamic studies of synthetic dye removal using pomegranate peel activated carbon prepared by microwave-induced KOH activation, Water Res. Ind. 6 (2014) 18-35.
[2] E. Forgacs, T. Cserhati, G. Oros, Removal of synthetic dyes from wastewaters: a review, Environ. Int. 30 (2004) 953-971.
[3] B. Noroozi, M. Aramin, S.H. Bahrami, Investigation on the capability of silkworm pupa as a natural adsorbent for removal dyes from textile effluent, Iran J. Chem. Eng. 1 (2004) 39-44.
[4] A.E. Yilmaz, R. Boncukcuoglu, M. Kocakerim, I.H. Karakas, Waste utilization: the removal of textile dye (complex red CR-L) from aqueous on sludge waste from electrocoagulation as adsorbent, Desalination 277 (2011) 156-163.
[5] V.K. Gupta Suhas, Application of low-cost adsorbents for dye removal - a review, J. Environ. Manag. 90 (2009) 2313-2342.
[6] F.T. De Oliveira, O. Chedeville, H. Fauduet, B. Cagnon, Use of zone/activated carbon coupling to remove diethyl phthalate from water: influence of activated carbon textural and chemical properties, Desalination 276 (2011) 359-365.
[7] G. Bhaskar, K.M. Raju, S.S. Thalamadai, S. Latha, S. Parvathy Prabhakar, Treatment of wastewater from synthetic textile industry by electrocoagulation-electrooxidation, Chem. Eng. J. 144 (2008) 51-58.
[8] M. Bayramoglu, M. Kobya, O.T. Can, M. Sozbir, Operating cost analysis of electrocoagulation of textile dye wastewater, Sep. Purif. Technol. 37 (2004) 117-125.
[9] G.H. Chen, Electrochemical technologies in wastewater treatment, Sep. Purif. Technol. 38 (2004) 11-41.
[10] M. Khemis, J.P. Leclerc, G. Tanguy, G. Valentin, F. Lapicque, Treatment of industrial liquid wastes by electrocoagulation: experimental investigations and an overall interpretation model, Chem. Eng. Sci. 61 (2006) 3602-3609.
[11] C.A. Martinez-Huitle, E. Brillas, Decontamination of wastewaters containing synthetic organic dyes by
electrochemical methods: a general review, Appl. Catal., B 87
(2009) 105-145.
[12] S. Zodi, O. Potier, F. Lapicque, J.-P. Leclerc, Treatment of the textile wastewaters by electrocoagulation: effect of operating parameters on the sludge settling characteristics, Sep. Purif. Technol. 69 (2009) 29-36.
[13] M. Carmona, M. Khemis, J.P. Leclerc, F.A. Lapicque, Simple model to predict the removal of oil suspensions from water using the electrocoagulation technique, Chem. Eng. Sci. 61 (2006) 1237.
[14] M.H. El-Naas, S. Al-Zuhair, A. Al-Lobaney, S. Makhlouf, Assessment of electrocoagulation for the treatment of petroleum refinery wastewater, J. Environ. Manage. 91 (2009) 180.
[15] M. Bayramoglu, M. Eyvaz, M. Kobya, Treatment of the textile wastewater by electrocoagulation. Economical evaluation, Chem. Eng. J. 128 (2007) 155.
[16] M. Kobya, M. Bayramoglu, M. Eyvaz, Techno-economical evaluation of electrocoagulation for the textile wastewater using different electrode connections, J. Hazard. Mater. (2007) 148311.
[17] B.K. Korbahti, Response surface optimization of electrochemical treatment of textile dye wastewater, J. Hazard. Mater. 145 (2007) 277.
[18] M. Yousuf, A. Mollah, J.A.G. Gomes, K.K. Das, D.L. Cocke, Electrochemical treatment of Orange II dye solution - use of aluminum sacrificial treatment electrodes and floc characterization, J. Hazard. Mater. 174 (2010) 851.
[19] P. Gao, X. Chen, F. Shen, G. Chen, Removal of chromium (VI) from wastewater by combined electrocoagulation-electroflotation without a filter, Sep. Purif. Technol. 43 (2005) 117.
[20] J.F. Martinez-Villafane, C. Montero-Ocampo, Optimisation of energy consumption in arsenic electro-removal from groundwater by the Taguchi method, Sep. Purif. Technol. 70
(2010) 302.
[21] T. Mariam, L.D. Nghiem, Landfill leachate treatment using hybrid coagulation-nanofiltration processes, Desalination 250 (2010) 677.
[22] A.E. Yilmaz, R. Boncukcuoglu, M.W. Kocakerim, B. Keskinler, The investigation of parameters affecting boron removal by electrocoagulation method, J. Hazard. Mater. 125 (2005) 160.
[23] W. Ma, F.Q. Ya, M. Han, R. Wang, Characteristics of equilibrium kinetics studies for adsorption of fluoride on magnetic-chitosan particle, J. Hazard. Mater. 143 (2007) 296.
[24] K.-W. Pi, Q. Xiao, H.-Q. Zhang, M. Xia, A.R. Gerson, Decolorization of synthetic Methyl Orange wastewater by electrocoagulation with periodic reversal of electrodes and optimization by RSM, Process Saf. Environ. Protect. PSEP-408 (2014) (No. of Pages 11).
[25] P. Canizares, C. Jimenez, F. Martinez, C. Saez, M.A. Rodrigo, Study of the electrocoagulation process using aluminum and iron electrodes, Eng. Chem. Res. 46 (2007) 6189-6195.
[26] S. Aoudj, A. Khelifa, N. Drauche, M. Hecini, H. Hamitouche, Electrocoagulation process applied to wastewater containing dyes from textile industry, Chem. Eng. Process. 49 (2010) 11761182.
[27] M. Chafi, B. Gourich, A. Essadki, C. Vial, A. Fabregat, Comparision of electrocoagulation using iron and aluminum electrodes with chemical coagulation for the removal of a highly soluble acid dye, Desalination 281 (2011) 285-292.
[28] H.-J. Liu, J.-H. Qu, C.-Z. Hu, S.-J. Zhang, Characteristics of manosized polyaluminum chloride coagulant prepared by electrolysis process, Colloids Surf., A 216 (2003) 139-147.
[29] B. Zeboudji, N. Drouiche, H. Lounici, N. Mameri, N. Ghaffour, The influence of parameters affecting boron removal by electrocoagulation process, Sep. Sci. Technol. 48 (2013) 12801288.
[30] W.-M. Zhang, J.-X. Zhuang, Q. Chen, S. Wang, W.-G. Song, L.-J. Wan, Cost-effective production of pure Al13 from AlCl3 by electrolysis, Ind. Eng. Chem. Res. 51 (2012) 11201-11206.
[31] Z.-R. Guo, G. Zhang, J. Fang, X. Dou, Enhanced chromium recovery from tanning wastewater, J. Clean. Prod. 14 (2006) 7579.
[32] B. Gao, B. Liu, T. Chen, Q. Yue, Effect of aging period on the characteristics and coagulation behavior of polyferric chloride and polyferric chloride-polyamine composite coagulant for synthetic dying wastewater treatment, J. Hazard. Mater. 187 (2011) 413-420.
[33] Y. Avsar, U. Kurt, T. Gonullu, Comparison of classical chemical and electrochemical processes for treating rose processing wastewater, J. Hazard. Mater. 148 (2007) 340-345.
[34] M.Y.A. Mollah, R. Schennach, J R. Parga, D.L. Cocke, Electrocoagulation (EC) - science and applications, J. Hazard. Mater. 84 (2001) 29-41.
[35] P.K. Holt, G.W. Barton, C.A. Mitchell, The future for electrocoagulation as a localized water treatment technology, Chemosphere 59 (2005) 355-367.
[36] M.Y.A. Mollah, P. Morkovsky, J.A.G. Gomes, M. Kesmez, J. Pargad, D.L. Cocke, Fundamentals, present and future perspectives of electrocoagulation, J. Hazard. Mater. 114 (2004) 199-210.
[37] O. Groterud, L. Smoczynski, Phosphorous removal from water by means of electrolysis, Water Res. 20 (1986) 667-669.
[38] M.S. Secula, I. Cretescu, B. Cagnon, L.R. Manea, C.S. Stan, I.G. Breaban, Fractional factorial design study on the performance of GAC-enhanced electrocoagulation process involved in color removal from dye solutions, Materials 6 (2013) 2723-2746.
[39] N.V. Narayanan, M. Ganesan, Use of adsorption using granular activated carbon (GAC) for the enhancement of removal of chromium from synthetic wastewater by electrocoagulation, J. Hazard. Mater. 161 (2009) 575-580.
[40] M.S. Secula, B. Cagnon, T.F. de Oliveira, O. Chedeville, H. Fauduet, Removal of acid dye from aqueous solutions by electrocoagulation/GAC adsorption coupling: kinetics and electrical operating costs, J. Taiwan Inst. Chem. E. 43 (2012) 767-775.
[41] O. Apaydin, U. Kurt, M.T. Gonullu, An investigation the treatment of tannery wastewater by electrocoagulation, Glob. NEST J. 11 (2009) 546-555.
[42] M.S. Secula, I. Cretescu, S. Petrescu, Electrocoagulation treatment of sulfide wastewater in a batch reactor: effect of electrode material on electrical operating costs, Environ. Eng. Manag. J. 11 (2012) 1485-1491.
[43] F.R. Espinoza-Quinones, M.M.T. Fornari, A.N. Modenes, S.M. Palacio, F.G. da Silva Jr., N.A.D. Szymanski, N. Kroumov, D.E.G. Trigueros, Pollutant removal from tannery effluent by electrocoagulation, Chem. Eng. J. 151 (2009) 59-65.
[44] K. Govindan, Y. Oren, M. Noel, Effect of dye molecules and electrode material on the settling behavior of flocs in an electrocoagulation induced settling tank reactor (EISTR), Sep. Purif. Technol. (2014), http://dx.doi.org/10.1016/j.seppur.2014. 04.046.
[45] N. Balasubramanian, T. Kojima, C. Ahmed Basha, C. Strinivasakannan, Removal of arsenic from aqueous solution using electrocoagulation, J. Hazard. Mater. 167 (2009) 966.
[46] G. Socrates, Infrated Charateristic Group Frequencies, Wiley-Interscience Publication, New York, 1980.
[47] P. Maha Lakshmi, P. Sivashanmugam, Treatment of oil tanning effluent by electrocoagulation: influence of ultrasound and hybrid electrode on COD removal, Sep. Purif. Technol. 116 (2013) 378-384.
[48] J. Beltran-Heredia, J.S. Martin, Azo dye removal by Moringa Oleifera Seed extract coagulation. Society and Colourists, Color. Technol. 124 (2008) 310-317.
[49] J. Basiri Parsa, M. Rezaei, A.R. Soleumani, Electrochemical oxidation of an azo dye in aqueous media investigation of operational parameters and kinetics, J. Hazard. Mater. 168 (2009) 997-1003.
[50] M. Panizza, G. Cerisola, Removal of organic pollutants from industrial wastewater by electrogenerated fento's reagent, Water Res. 35 (2001) 3987-3992.
[51] R. Cossu, A.M. Palcaro, M.C. Lavagnolo, S. Palmas, F. Ronoldi, Electrochemical treatment of landfill leachate: oxidation at Ti/PbO2 and Ti/SnO2 anodes, Environ. Sci. Technol. 32 (1998) 3570-3573.
[52] J. Basiri Parsa, H. Rezaei Vahidian, A.I.R. Soleymani, M. Abbasi, Removal of Acid Brown 14 in aqueous media by electrocoagulation: optimization parameters and minimizing of energy consumption, Desalination 278 (2011) 295-302.
[53] J. Jiang, N. Graham, C. Andre, G.H. Kelsall, N. Brandon, Laboratory study of electrocoagulation-flotation for water treatment, Water Res. 36 (2002) 4064-4078.
[54] H.A. Moreno-Casillas, D.L. Cocke, J.A.G. Gomes, P. Morkovsk, J.R. Parga, E. Peterson, Electrocoagulation mechanism of COD removal, Sep. Purif. Technol. 56 (2007) 204.
[55] M. Khemis, J.P. Leclerc, G. Tanguy, G. Vatentin, F. Lapicque, Treatment of industrial liquid wastes by electrocoagulation: experimental investigations and an overall interpretation model, Chem. Eng. Sci. 61 (2006) 3602.
[56] M.S. Secula, I. Cretescu, S. Petrescu, An experimental study of Indigo carmine removal from aqueous solution by electrocoagulation, Desalination 277 (2010) 227.